Flamebar Benefits Authorities Having Jurisdiction (AHJs)

Minimize Inspection Delays with Flamebar

Flamebar fire-rated HVAC systems offer safety and efficiency for modern buildings. Our systems comply with the latest ASHRAE 15-2022 standard, as well as the newest mechanical codes that require the protection of line sets charged with next generation flammable A2L refrigerants. Flamebar systems always meet symmetry requirements of the building code, eliminating the need for traditional fire blankets or wraps, streamlining installation, and reducing material and installation costs.

Flamebar benefits AHJs by simplifying the review, inspection, and approval processes for fire-rated HVAC systems. Its compliance with applicable codes and standards means that AHJs can more easily verify that projects meet regulatory requirements. The streamlined installation process and reduced need for additional fireproofing materials make inspections quicker and less complex. Flamebar offers clear documentation and proven performance in fire resistance, providing AHJs confidence in the system’s reliability, eliminating compliance questions and leading to smoother inspection and certification processes. This efficiency helps AHJs ensure building safety while minimizing delays and administrative burden.

Flamebar Compliant Fire-Rated HVAC Systems

Flamebar simplifies the HVAC installation process, helping projects stay on budget and within deadlines. Integrated fire-rated duct systems reduce the need for additional fireproofing materials, cutting down on overall material costs and minimizing labor expenses. With Flamebar, designs are assured of reliable, cost-effective fire safety compliance.

When reviewing Flamebar fire-rated HVAC systems, AHJs can have confidence that Flamebar is compliant with codes, including applicable ASTM and ISO standards designed to prevent the spread of fire and smoke through ductwork. Flamebar A2L enclosures protect against fire and also contain flammable refrigerants in the event of leaks as required by code.

Simplified Regulatory Verification for AHJs with Flamebar

Flamebar simplifies the review, inspection, and approval processes for AHJs by complying with stringent fire safety codes and standards, making regulatory verification easier.

COMPLIANT FIRE-RATED HVAC SYSTEMS

Flamebar is compliant with the latest fire safety regulations, including ASHRAE 15-2022 as well as building and mechanical codes referencing the protection of line sets charged with mildly flammable A2L refrigerants Flamebar systems ensure reliable, standardized, fire-rated HVAC system performance.

REDUCED INSPECTION TIME

The streamlined installation process and reduced need for additional fireproofing materials make inspections quicker and less complex for AHJs.

SMOOTH CERTIFICATION PROCESS

Flamebar’s clear documentation and proven fire resistance performance provide AHJs with confidence, leading to smoother certification and fewer compliance issues.

SUPPORT FOR AHJs

Flamebar provides comprehensive support for AHJs to ensure smooth plan review, inspection, and compliance verification. Our systems meet all necessary codes and standards, making the approval process straightforward.

TESTING APPROVALS AND LISTINGS

Fire-rated ducts and enclosure systems are designed and installed to protect building occupants and property from fire hazards. Flamebar is thoroughly tested according to the following standards and listings:

ASTM E119Fire Test of Building Construction and Materials
ASTM E84/UL723Surface Burning Characteristics
– Flame Spread (Intertek)
– Smoke Spread (Intertek)
ASTM E814Firestop Test
ASTM E136Non Combustibility Test
ASTM C518Durability Test
ASTM E2336Fire Resistive Grease Duct Enclosure Systems

UL Listings

Ventilation Duct Assemblies Certified for CanadaHNLJ7.V-1
Uninsulated Ventilation Duct AssembliesHNLN.V-5
Uninsulated Ventilation Duct AssembliesHNLN.V-18
XHEZ.C-AJ-7154, 7192, 7195, 7023, 7027, 7106, 7107, 7114, 7143, 7156, 7171
XHEZ.W-J- 7109, 7152, 7155, 7250, 7025, 7026, 7033, 7149, 7164, 7202

Intertek Listings

ASTM E119 Riser DuctFIL/FMF 120-10
ASTM E814 Through Penetration Fire Stop SystemFIL/FMF 120-09
ASTM E2336 Grease DuctFIL/FMF 120-01, 02, 03, 04
UL1978Test Standard for Grease Ducts (Intertek)
ISO 6944 (1985)Fire Resistive Tests Ventilation Ducts
ISO 6944-01 (2008)Fire Resistive Tests Ventilation Ducts
Through Penetration Fire Stop SystemXHEZ.F-B-7005
Through Penetration Fire Stop SystemXHEZ.F-B-7017
Through Penetration Fire Stop SystemXHEZ.F-B-7029
Through Penetration Fire Stop SystemXHEZ.F-B-7030
Through Penetration Fire Stop SystemXHEZ.W-L-7133
Through Penetration Fire Stop SystemXHEZ.W-L-7160
Through Penetration Fire Stop SystemC-AJ-7094
Intertek SPEC ID16257
ISO 6944-01:
Rectangular
Uninsulated 2 hour B (vertical)FIL/FMF 120-11
Uninsulated 2 hour B (horizontal)FIL/FMF 120-12
Uninsulated 2 hour A (vertical)FIL/FMF 210-01
Uninsulated 2 hour A (horizontal)FIL/FMF 150-01
Uninsulated 4 hour B (vertical)FIL/FMF 240-02
Uninsulated 4 hour B (horizontal)FIL/FMF 240-01
Round
Uninsulated 4 hour B (vertical)FIL/FMF 240-03
Uninsulated 4 hour B (horizontal)FIL/FMF 240-04
Uninsulated 2 hour A (vertical)FIL/FMF 150-02
Uninsulated 2 hour A (horizontal)FIL/FMF 120-13

Contact us to discuss how Conquest can help with your next project